Journal Article


Evaluation of cavitation erosion behavior of commercial steel grades used in the design of fluid machinery

Abstract

The erosion response under cavitation of different steel grades was assessed by studying the erosion rate, the volume removal, the roughness evolution, and the accumulated strain energy. A 20 kHz ultrasonic transducer with a probe diameter of 5 mm and peak-to-peak amplitude of 50 μm was deployed in distilled water to induce damage on the surface of commercial chromium and carbon steel samples. After a relatively short incubation period, cavitation induced the formation of pits, cracks, and craters whose features strongly depended on the hardness and composition of the tested steel. AISI 52100 chromium steel showed the best performance and is, therefore, a promising design candidate for replacing the existing fluid machinery materials that operate within potential cavitating environments.

Attached files

Authors

Tzanakis, I
Bolzoni, L
Eskin, G
Hadfield, M

Oxford Brookes departments

Faculty of Technology, Design and Environment\Department of Mechanical Engineering and Mathematical Sciences

Dates

Year of publication: 2017
Date of RADAR deposit: 2017-05-09


Creative Commons License This work is licensed under a Creative Commons Attribution 4.0 International License


Related resources

This RADAR resource is the Version of Record of Evaluation of cavitation erosion behavior of commercial steel grades used in the design of fluid machinery

Details

  • Owner: Rosa Teira Paz
  • Collection: Outputs
  • Version: 1 (show all)
  • Status: Live
  • Views (since Sept 2022): 469